Publisher profile
BC Hydro
Applies to: British Columbia, Canada
Is this your organization? Raise a concern or correction
Item standards
- Complex Revenue Metering
- CS-1684Underground Transformation Options for Space Constrained Urban Developments
- DGI 100kW and Below100 kW and below Distribution Generation Interconnection Requirements
- DGI Islanding GuidelinesDistribution Power Generator Islanding Guidelines
- DGI RequirementsDistribution Generator Interconnection Requirements
- DGI Requirements Amendment 1Distribution Generator Interconnection Requirements Amendment 1
- DGI Requirements Amendment 2Amendment 2 Requirements for terminals supplying ships capable of running in parallel with BC Hydro (CTT Shore Power)
- ES43 BES43 B - Clearances
- ES43 B1-02Standard Vertical Sag Criteria for Wires and Conductors Above Ground and Roads
- ES43 B1-03Vertical Design Clearances of Wires and Conductors Above Ground
- ES43 B1-11Clearances Above Ground for Low-Voltage Services
- ES43 B1-12Clearances Over Railway Crossings
- ES43 B1-13Vertical Separation Between Power Conductors and Communication Lines Attached to
- ES43 B1-14Minimum Separation from Flammable Dielectric-Filled Equipment to Buildings
- ES43 B1-15Minimum Clearance for Conductors to Buildings, Signs, Billboards, Lamp and Traffic Sign
- ES43 B1-16Vertical Separation Between Conductors Carried on Separate Supports
- ES43 CES43 C - Joint and Secondary Use
- ES43 C1-02Equipment Boxes on Poles
- ES43 C1-04Messenger Supported Clearance Contact for Multiplex Cable Service Drop
- ES43 C1-05Climbing and Working Space
- ES43 C2-01Spacing and Separation - Wire Spacing on Joint-Use Pole Below the Neutral
- ES43 C2-02Spacing and Separation - In-Span Separation Between Secondary/Neutral Conductors and Communication Wires
- ES43 C2-03Spacing and Separation - Typical Vertical Wire Separation at a Joint-Use Pole between BC Hydro and TELUS
- ES43 C2-04Spacing and Separation - Typical Vertical Wire Separation at a Joint-Use Pole for BC Hydro, TELUS, and Third- Party Communications Licensee Plant
- ES43 C3-01Antenna Installation - General Requirements
- ES43 C3-02Antenna Installation - Three-Phase Alley Arm
- ES43 C3-03Antenna Installation - Three-Phase Alley Arm Single-Phase Transformer
- ES43 C3-04Antenna Installation - Three-Phase Flat
- ES43 C3-05Antenna Installation - Three-Phase Flat Single-Phase Transformer
- ES43 C3-06Antenna Installation - Single-Phase Armless
- ES43 C3-07Antenna Installation - Single-Phase Armless Single-Phase Transformer
- ES43 C3-08Antenna Installation - Grounding
- ES43 C4-01Mid-Pole Antenna - Design and Installation Requirements
- ES43 C5-01Strand-Mounted Antenna - Design and Installation
- ES43 J7-01ES43 J7-01 - Primary Revenue Metering
- ES43 KES43 K - Protection and Switching
- ES43 LES43 L - Street Lighting
- ES43 M1-10ES43 M1-10 - Terminal Poles Pilaster Location
- ES43 N1ES43 N1 - General
- ES43 N2ES43 N2 - Service Connections
- ES43 N2-01Service Connections - Typical Secondary Structures
- ES43 N2-02Service Connections - Single Multiplex Services Taken from Secondary Bus
- ES43 N2-03Service Connections - Single Triplex Service Taken Direct from Transformer
- ES43 N2-04Service Connections - Multiple Triplex Service Taken Direct from Transformer
- ES43 N2-05Service Connections - Parallel Multiplex Services and Customer Masts
- ES43 N2-06Service Connections - Copper Open Wire Service
- ES43 N2-07Service Connections - Underground Services from Overhead Secondaries and Transformers
- ES43 N2-08Service Connections - H-Frame Transformer Platform Secondary Bus
- ES43 N2-09Service Connections - Service Pole Attachment and Mid-Span Tap
- ES43 N2-10Service Connections - Terminal Pole Feeder or UD/URD or Mid-Span Service Taps
Approved products
26 products carry a BC Hydro approval.
- CT Meter Socket with Test Switch, Single-PhaseTSU5Eaton
- CT Meter Socket with Test Switch, Single-PhaseCTS405PW-BCHydel Inc.
- CT Meter Socket with Test Switch, Single-PhaseCT105-LMicrolectric (ABB Electrification Canada)
- CT Meter Socket, 3-Phase 3-Wire DeltaTSU8Eaton
- CT Meter Socket, 3-Phase 3-Wire DeltaCT108-LMicrolectric (ABB Electrification Canada)
- CT Meter Socket, 3-Phase 3-Wire DeltaCTS800PW-BCHydel Inc.
- CT Meter Socket, 3-Phase 4-WireTSU13Eaton
- CT Meter Socket, 3-Phase 4-WireCTS130PWHydel Inc.
- CT Meter Socket, 3-Phase 4-WireCT113-LMicrolectric (ABB Electrification Canada)
- Self-Contained Combination Meter Socket and Breaker PanelLS820-BRC (200A)Leviton
Reference only. Always verify before you specify.
This directory is compiled from publicly available sources and may contain errors, omissions, or out-of-date entries. FieldWorks does not publish, approve, certify, or endorse any standard or product; approval listings are reproduced from the issuing authority's own published lists. Confirm the current edition with the publisher or authority before relying on it in a contract, and use the flag buttons in the directory to report anything that looks wrong. Use of the directory is subject to our Terms of Service, including the prohibition on bulk extraction and automated scraping.
Put this standard to work.
This same search is built into the FieldWorks Item Specification Composer, where a pick becomes a tender item with the reference, unit, and special provision already wired.
