Publisher profile
Georgia Department of Transportation
Applies to: Georgia, United States
Is this your organization? Raise a concern or correction
General provisions
Item standards
- 02-0000Special Design Details Index
- 1001bPipe Culvert Concrete Headwall
- 1004aRubble Masonry Headwalls for Pipe Culverts
- 1010Catch Basins (With Cast Iron Grate Inlets)
- 1011aBrick Manholes
- 1011apPrecast Reinforced Concrete Manhole
- 1013Catch Basins (With Castings)
- 1017Pipe Arch Culverts Concrete Endwalls
- 1018bSand Cement Bag Rip Rap for Endwall and Apron
- 1019aDrop Inlets
- 1019apPrecast Drop Inlets
- 1019bDrop Inlets Types V-1 and V-2
- 1029aRip Rap for Structural Plate Pipe and Pipe Arch Culverts
- 1030pThermoplastic Pipe (1030p)
- 1033bCatch Basins (Max. Pipe Conn. - 18" may be used in 4' Median)
- 1033dCatch Basins (For use with 6" or 8" Ht. curb and gutter)
- 1033dpPrecast Catch Basins (For use with 6" or 8" Precast Ht. curb and gutter)
- 1033eCatch Basins (For use with 4" Ht. curb and gutter)
- 1033epPrecast Catch Basins (For use with 4" Ht. Precast curb and gutter)
- 1033fCatch Basins (For use with Header or Integral curbs, 4", 6", 8", or 10" Ht.)
- 1033fpPrecast Catch Basins (For use with Header or Precast Integral curbs, 4", 6", 8", or 10" Ht.)
- 1033gCatch Basins (For use with 6" mountable curb and gutter.)
- 1033gpPrecast Cast Basins (For use with 6" mountable Precast curb and gutter.)
- 1034dCatch Basins (For use with 6" or 8" curb and gutter in sags or low points)
- 1034dpPrecast Catch Basins (For use with 6" or 8" curb and Precast gutter in sags or low points)
- 1034eCatch Basins (For use with 4" Ht. curb and gutter in sags or low points)
- 1034epPrecast Catch Basins (For use with 4" Ht. curb and gutter in sags or low points)
- 1034fCatch Basins (For use with 4", 6", 8" or 10" Ht. Header or Integral Curbs, (In sags or low points)
- 1034fpPrecast Catch Basins - For use with 4", 6", 8" or 10" Ht. Header or Integral Curbs (In sags or low points)
- 1034gCatch Basins - For use with Curb (6" mountable) and Gutter (In sags or low points)
- 1034gpPrecast Catch Basins - For use with Curb (6" mountable) & Gutter (In sags or low points)
- 1035Drain Inlet (Elbow type)
- 1040Circular Base Units and Risers for Catch Basins and Drop Inlets
- 1120Flared End Sections for Pipes
- 1122-1Safety End Section (Metal) (for Side Drain pipe-or Storm Drain Pipe Parallel to Mainline) (Sheet 1 of 3)
- 1122-2Safety End Section (Metal) (for Side Drain pipe-or Storm Drain Pipe Parallel to Mainline) (Sheet 2 of 3)
- 1122-3Safety End Section (Concrete) (for Side Drain pipe-or Storm Drain Pipe Parallel to Mainline) (Sheet 3 of 3)
- 1125Inlet Headwall - Outlet Headwall
- 1401Pavement Patching Details (Storm Drain or Utility Installations by Open Cut Across Existing Pavement)
- 2010-1Corrugated Metal Pipe Arch Culverts Spans 6 ft. 0 in. To 20 ft. 0 in. Inclusive (1 of 2)
- 2010-2Corrugated Metal Pipe Arch Culverts Spans 6 ft. 0 in. To 20 ft. 0 in. Inclusive (2 of 2)
- 2011bStructural Plate Pipe and Pipe Arch Culverts
- 2312Details For Extending Culverts (Raising Parapets or Lengthening Culverts 2' or less)
- 2317Details for Extending Concrete Box Culverts
- 2318Details for Extending Concrete Box Culverts With Skews below 75
- 2319aReinforced Concrete Box Culverts Quadruple 10' x 10'for Depths of Fill Up to 50 Feet (2319a)
- 2319bReinforced Concrete Box Culverts Quadruple 10' x 10'for Depths of Fill Up to 50 Feet (2319b)
- 2320aReinforced Concrete Box Culverts Double 10' x 8', 10' x 9', and 10' x 10' for Depths of Fill Up to 50 Feet (2320a)
- 2320bReinforced Concrete Box Culverts Double 10' x 8', 10' x 9', and 10' x 10' for Depths of Fill Up to 50 Feet (2320b)
- 2320cReinforced Concrete Box Culverts Double 10' x 8', 10' x 9', 10' x 10' for 45, 60 and 75 Deg Skews (2320c)
Reference only. Always verify before you specify.
This directory is compiled from publicly available sources and may contain errors, omissions, or out-of-date entries. FieldWorks does not publish, approve, certify, or endorse any standard or product; approval listings are reproduced from the issuing authority's own published lists. Confirm the current edition with the publisher or authority before relying on it in a contract, and use the flag buttons in the directory to report anything that looks wrong. Use of the directory is subject to our Terms of Service, including the prohibition on bulk extraction and automated scraping.
Put this standard to work.
This same search is built into the FieldWorks Item Specification Composer, where a pick becomes a tender item with the reference, unit, and special provision already wired.
