Publisher profile
Halton Hills Hydro Inc.
Applies to: Halton Hills, Halton Region, Ontario, Canada
Is this your organization? Raise a concern or correction
Item standards
- 19u-525Single Phase Padmounted Transformer Clearances
- 19u-527sSwitchgear - Construction Site Protection
- 19u-527tTransformer - Construction Site Protection
- 25u-166Bulk Metering Cabinet, 400A - 600A, Industrial/Commercial Service
- 25u-206.3Meter Cabinet Configuration, 400A - 600A, General Service
- 25U-227Meter Installation, General Service < 50kW, 200A, Industrial/Commercial Service
- 25U-228Meter Installation, General Service > 50kW, 200A, Industrial/Commercial Service
- 3-105Minimum Conductor Clearances from Buildings and Structures
- 37-145Three Phase Transformer and Switching Cubicles Clearances
- 37-318Typical Guard Post Installation
- UD-01Typical Concrete Encased Duct Bank Section (8 ducts) - Roadcrossing/Boulevard
- UD-02Concrete Encase Duct Bank Arrangements
- UD-03Hydro, Bell & TV Joint Use Trench Section 1.200 m Depth, Direct Buried Ducts, Boulevard
- UD-04Hydro, Bell & TV Joint Use Trench Section 1.425 m Depth, Direct Buried Ducts, Boulevard
- UD-05Hydro, Bell & TV Joint Use Trench Section 1.675 m Depth, Direct Buried Ducts, Boulevard
- UD-06Secondary Service Trench Section
- UD-07Street Lighting Trench Section
- UD-08Street Lighting Duct Termination Detail
- UD-09Secondary Service Installation Detail for Single Phase up to 400A and three Phase up to 200A
- UD-09-RECSecondary Service Installation Detail (Recessed) for 1 Phase (& 3 Phase up to 200 AMP)
- UD-09BSecondary Service on Stub Pole Installation Detail for 1 Phase (& 3 Phase up to 200A)
- UD-09CCMS Secondary Service on Stub Pole Installation Detail for 1 Phase
- UD-09DSecondary Service Installation Detail for 1 Phase (up to 400A)
- UD-09EGanged Meter Base (3 Position Max. + Entry Door), Secondary Service on Wood Structure - Installation Detail
- UD-10Secondary Service Cable Splice Detail
- UD-11Installation of Precast Foundation for Pad Mounted Transformer & Switchgear Including Grounding Detail
- UD-12Proposed Typical Lot Servicing Agreement (Future)
- UD-13Single Phase Low Profile Pad Mounted Transformer
- UD-14Secondary Underground Cable Termination
- UD-15Primary Underground Termination Pole
- UD-16Typical 1 Phase Low Profile Pad Mounted Transformer Installation
- UD-17Typical 3 Phase Pad Mounted Transformer Installation (Radial & Loop Feed)
- UD-18BTypical Canada Power Pad Mounted Switchgear with Resettable Fault Interrupter Installation Detail
- UD-18CCanada Power Pad Mounted Switchgear, 2 - 600A 3 Loop Feed with Resettable Fault Interrupters on 6 - 200A Single Phase Taps
- UD-18DCanada Power Pad Mounted Switchgear, 2 - 600A 3 Loop Feed with Resettable Fault Interrupters on 1 - 200A 3 Tap and 3 - 200A Switchable Single Phase Taps
- UD-19Faulted Circuit Indicator Installation Details
- UD-20Typical Switching Kiosk Installation
- UD-23Proposed Joint-Use Secondary Service Lateral (Step) Trench Section
- UD-24Proposed Joint Use Primary & Secondary Hydro, Bell, T.V., & Gas Concrete Encased Step Trench Section
- UD-25Proposed Joint Use Primary & Secondary Hydro, Bell, T.V., & Gas Step Trench Section (1.525m Depth) - Boulevard
- UD-26Proposed Concrete Encased Duct Bank Section Step Trench (For 8 Ducts) - Roadcrossing
- UD-27Concrete Foundation Standard (For Halton Hills Hydro 898 Series Canada Power Switchgear)
- UD-29Concrete Foundation Standard Lid (for Retrofitting PMH-9 Foundations with Lid for 898 Series Canada Power Switchgears)
- UD-30Directional Bore Street Crossing Secondary Services - Typical
- UD-31Directional Bore Street Crossing Primary Services - Typical
- UD-33Pull/ Splice Pit (Alongside Road/ Multi-Use Path/ Sidewalk)
- Underground Distribution Specifications
Reference only. Always verify before you specify.
This directory is compiled from publicly available sources and may contain errors, omissions, or out-of-date entries. FieldWorks does not publish, approve, certify, or endorse any standard or product; approval listings are reproduced from the issuing authority's own published lists. Confirm the current edition with the publisher or authority before relying on it in a contract, and use the flag buttons in the directory to report anything that looks wrong. Use of the directory is subject to our Terms of Service, including the prohibition on bulk extraction and automated scraping.
Put this standard to work.