Publisher profile
Sturgeon County
Applies to: Sturgeon County, Alberta, Canada
Is this your organization? Raise a concern or correction
Item standards
- 3.1.0TYPICAL URBAN SIGN INSTALLATION
- 3.1.1Collector and Arterial Intersection Cut Corner Detail
- 3.1.10TYPICAL CUL-DE-SAC -WALKWAY ON BOTH SIDES
- 3.1.12LOCAL RESIDENTIAL ROADWAY CUL-DE-SAC BULB CROSS SECTION
- 3.1.13PAVED RESIDENTIAL LANE AND ROADWAY STRUCTURE
- 3.1.14LOCAL RESIDENTIAL ROADWAY -21m RIGHT-OF-WAY, 10m ROADWAY, SEPARATE WALK
- 3.1.15LOCAL RESIDENTIAL ROADWAY -21m RIGHT-OF-WAY, 10m ROADWAY, MONOWALK
- 3.1.16LOCAL INDSUTRIAL/COMMERCIAL ROADWAY -22m RIGHT-OF-WAY, 11m ROADWAY, SEPARATE WALK
- 3.1.17LOCAL ROADWAY STRUCTURE
- 3.1.18MINOR RESIDENTIAL COLLECTOR ROADWAY -23m RIGHT-OF-WAY, 12m ROADWAY, SEPARATE WALK
- 3.1.19MAJOR RESIDENTIAL COLLECTOR ROADWAY -25m RIGHT-OF-WAY, 12.5m ROADWAY, SEPARATE WALK
- 3.1.20INDUSTRIAL/COMMERCIAL COLLECTOR ROADWAY -26m RIGHT-OF-WAY, 13.5m ROADWAY, SEPARATE WALK AND ASPHALT TRAIL
- 3.1.21MINOR AND MAJOR COLLECTOR ROADWAY STRUCTURE
- 3.1.22FOUR LANE DIVIDED COLLECTOR ROADWAY -32m RIGHT-OF-WAY, 2x7m ROADWAY, SEPARATE WALK AND ASPHALT TRAIL
- 3.1.23FOUR LANE DIVIDED COLLECTOR ROADWAY STRUCTURE
- 3.1.24FOUR LANE DIVIDED ARTERIAL ROADWAY -42m RIGHT-OF-WAY, 2x7.4m ROADWAY, ASPHALT TRAIL
- 3.1.25FOUR LANE DIVIDED ARTERIAL ROADWAY STRUCTURE
- 3.1.26EMERGENCY VEHICLE ACCESS PUBLIC UTILITY LOT ROADWAY STRUCTURE
- 3.1.3Rapid Flashing Beacon
- 3.2.0LANE CROSSING -SEPARATE WALK
- 3.2.1LANE CROSSING -MONOWALK
- 3.2.10125mm Standard & 80mm Low Profile Mountable Curb and 250mm Gutter
- 3.2.11150mm Standard Curb and 250mm Gutter & Reverse Gutter
- 3.2.12200mm Standard Curb and 250mm Gutter & Reverse Gutter
- 3.2.13150mm Standard Curb and 500mm Gutter
- 3.2.1440mm Drop Curb and 250mm Gutter
- 3.2.15Monolithic Walk with 125mm Standard Mountable Curb and Gutter
- 3.2.16Monolithic Walk with 80mm Low Profile Mountable Curb and Gutter
- 3.2.17Monolithic Walk with 150mm Standard Curb and Gutter
- 3.2.2RESIDENTIAL CROSSING -SEPARATE WALK
- 3.2.3RESIDENTIAL CROSSING -MONOWALK
- 3.2.4COMMERCIAL CROSSING -SEPARATE WALK
- 3.2.5COMMERCIAL CROSSING -MONOWALK
- 3.2.6TYPICAL CONCRETE WALKWAY -1.8m
- 3.2.7Depressed Curb & Gutter for Catch Basin
- 3.2.9Standard Curb Ramp
- 3.3.0Typical Lot Grading Types
- 3.3.1Typical Walk-Out Basement Lot Grading (Type 4)
- 3.4.0STANDARD TRENCH FOR CIRCULAR PIPE
- 3.4.1STANDARD TRENCH BEDDING FOR CIRCULAR PIPE
- 3.4.2Typical Casing Pipe with Insulator
- 3.4.3Typical Single Family Lot Residential Services (Single and Dual)
- 3.4.4Typical Single Family Lot Residential Service Profile
- 3.5.0Typical Hydrant Bollard Layout
- 3.5.1Typical Hydrant Connection and Valve Placement
- 3.5.10VERTICAL BEND CONCRETE THRUST BLOCKS
- 3.5.11STAINLESS STEEL CLAMP DETAIL FOR VERTICAL BEND THRUST BLOCKS
- 3.5.12REDUCER AND TRANSITION COUPLING CONCRETE THRUST BLOCKS
- 3.5.2TYPICAL BLOW OFF VALVE
- 3.5.3TYPICAL AIR RELEASE VALVE AND VALVE CHAMBER
Reference only. Always verify before you specify.
This directory is compiled from publicly available sources and may contain errors, omissions, or out-of-date entries. FieldWorks does not publish, approve, certify, or endorse any standard or product; approval listings are reproduced from the issuing authority's own published lists. Confirm the current edition with the publisher or authority before relying on it in a contract, and use the flag buttons in the directory to report anything that looks wrong. Use of the directory is subject to our Terms of Service, including the prohibition on bulk extraction and automated scraping.
Put this standard to work.
This same search is built into the FieldWorks Item Specification Composer, where a pick becomes a tender item with the reference, unit, and special provision already wired.
