Publisher profile
Town of Oakville
Applies to: Oakville, Halton Region, Ontario, Canada
Is this your organization? Raise a concern or correction
Item standards
- Development Engineering Procedures and Guidelines
- Forestry Std. 10ACrown Correction Detail
- Forestry Std. 10BCrown Correction - High Branched
- Forestry Std. 10CCrown Correction - Low Branch
- Forestry Std. 10DCrown Correction - Low Branched Multi
- Forestry Std. 11ATree Protection Barriers
- Forestry Std. 1ATree Planting on Private Property
- Forestry Std. 2ADeciduous Tree Parks
- Forestry Std. 3ATree Planting in Typical Parking Lot Island
- Forestry Std. 4ATree Planting in Typical Streetscape Using Soil Cells
- Forestry Std. 5A2.25m Wide Public Boulevard Tree Planting Detail
- Forestry Std. 5B2.25m Wide Public Boulevard Tree Planting Detail Using Breakout Zone
- Forestry Std. 5C2.55m Wide Public Boulevard Tree Planting Detail
- Forestry Std. 5D2.55m Wide Boulevard Tree Planting Detail Using Breakout Zones
- Forestry Std. 6AConifer Tree Planting
- Forestry Std. 7ATree in Poorly Drained Soil
- Forestry Std. 7BTree With Berm (Existing Soil Modified)
- Forestry Std. 7DTree On Slope 5% (20:1) To 50% (2:1)
- Forestry Std. 9ARoot Ball Shaving Container Detail
- Forestry Std. 9BRoot Correction Detail - Container
- Forestry Std. 9DRoot Observation Details - Balled and Burlapped
- Forestry Std. 9ERoot Observation Detail - Container
- Livable by Design Manual (Part C)Livable by Design Manual (Part C): Site Design and Development Standards
- STD 2-1Semi Pre-Construction Manhole (825mm Diameter to 2700mm Diameter Pipe)
- STD 2-2Drop Structures for Manholes
- STD 3-1Pre-Cast Catchbasin - No Sump
- STD 3-2Cast in Place Catchbasin - No Sump
- STD 3-3Cast in Place Ditch Inlet
- STD 3-4Catchbasin Connection Detail
- STD 4-1Typical Beam Support of Existing Service
- STD 5-1Bird Cage Catchbasin Top
- STD 5-2Beehive Catchbasin Top
- STD 6-1Two Stage Extruded Curb and Gutter
- STD 6-2Sub-Drains
- STD 6-3Concrete Sidewalk Details
- STD 6-4Concrete Walkway Details
- STD 6-5Standard Bicycle Path
- STD 6-6Concrete Headwall Under 1.5m Sidewalk (Extended Culvert)
- STD 6-7Concrete Headwall Under 1.5m Sidewalk
- STD 6-8Reinforced Concrete Headwall (for Driveway Culverts)
- STD 7-118m Road Allowance
- STD 7-13aInterim Street Section for 16m Road Allowance
- STD 7-1a16m Road Allowance
- STD 7-220m Road Allowance
- STD 7-21aResidential Laneway 7.5m Right of Way
- STD 7-21bCommercial Laneway 12.0m Right of Way
- STD 7-22aLocal Roadway 17.0m Right of Way Modified Boulevard Space
- STD 7-22bLocal Roadway 20.0m Right of Way Employment Areas
- STD 7-23Connector Transit Corridor 19.0m Right of Way
- STD 7-24Avenue Transit Corridor 22.0m Right of Way General Urban and Sub-Urban, Neighbourhood Centre and Employment Areas
Approved products
1 product carry a Town of Oakville approval.
- Geotextile Filter Fabric360RTerrafix Geosynthetics Inc.
Reference only. Always verify before you specify.
This directory is compiled from publicly available sources and may contain errors, omissions, or out-of-date entries. FieldWorks does not publish, approve, certify, or endorse any standard or product; approval listings are reproduced from the issuing authority's own published lists. Confirm the current edition with the publisher or authority before relying on it in a contract, and use the flag buttons in the directory to report anything that looks wrong. Use of the directory is subject to our Terms of Service, including the prohibition on bulk extraction and automated scraping.
Put this standard to work.
This same search is built into the FieldWorks Item Specification Composer, where a pick becomes a tender item with the reference, unit, and special provision already wired.
